Blog
Application Standard of Ozone Dosage
Application Standard
Ozone concentration use on Space purifier, equipment, Container disinfection, fresh keeping, odour removal ( 1PPM=2.14mgL);
Application | Type | Ozone Concentration(PPM) | Ozone Dosage (mg/H) | Method of Application |
disinfection | medical appliance | 20 | 50-100 | Ozone concentration 20ppm, disinfection time 60minutes; |
cold storage |
| 6-10 | 15-25 | Continuous operation according to capacity and pollution degree, mainly for killing fungus; |
food processing workshop |
| 1.1-1.5 | 2.5-3.5 | Turn off ozone generator after work every day. |
sickroom,operation room |
| 2.5-5 | 5.5-15 | Turn off ozone generator when needs sterilization. |
work clothes |
| 10-20 | 25-50 | Relative humidity about 90%, hanging clother with a hanger; |
food preservation | general purpose | 1-2 | 2.5-5 | Turn on ozone generator on a regular basis. |
egg |
| 2-2.5 | 5-5.5 | Supply ozone gas on an interval basis, boot 2-3 times a day. |
banana |
| 2.5-3.5 | 5.5-8 |
|
apple |
| 2.0 | 5 |
|
vegetables |
| 1.5-1 | 2.5-3.5 |
|
fish & cheese |
| 0.5-1 | 1.5-2.5 |
|
deodorization & purification | morgue | 3 | 7 | Boot the ozone generator when smelling odor. |
fish-processing plant |
| 3 | 7 | If gaseous pollutants enter into processing channel,adding ozone gas in the channel to remove odor.If the odor is paticularsly smelly in the workshop,add ozone gas in the air inlet. |
butchering room |
| 2-3 | 5-7 |
|
fatty acid plants |
| 10 | 25 |
|
rubber plant |
| 3-10 | 7-25 |
|
garbage and waste disposal |
| 10 | 25 |
|
sewage treatment plant |
| 12 | 2.5-5 |
|